# 40 CFR 1065.370 CLD CO2 and H2O quench verification.

40 CFR 1065.370 CLD CO2 and H2O quench verification., “CLD CO2 and H2O quench verification”, is a CFR section of [40 CFR Part 1065, Subpart D, Subject Group: NOX and N2O Measurements—NOX and N2O Measurements](https://ontology.bommaritollc.com/id/01a0f0af-c632-7305-a025-04a52b6b4ebe); in force.

IRI: <https://ontology.bommaritollc.com/id/01a0f0b0-6d7d-73a2-90f0-307f63992b83>

Within: [Title 40—Protection of Environment](https://ontology.bommaritollc.com/id/01a0f0af-ab93-7690-8acc-6de5e51a64c2) › [40 CFR Chapter I—ENVIRONMENTAL PROTECTION AGENCY](https://ontology.bommaritollc.com/id/01a0f0af-abe5-75b3-9f43-df69d57b62ce) › [40 CFR Chapter I, Subchapter U—AIR POLLUTION CONTROLS](https://ontology.bommaritollc.com/id/01a0f0af-c54b-73db-ab0f-d9be6da01ab1) › [40 CFR Part 1065—Engine-testing procedures](https://ontology.bommaritollc.com/id/01a0f0af-ca60-77ec-b94e-4b7ee66d0648) › [40 CFR Part 1065, Subpart D—Calibrations and Verifications](https://ontology.bommaritollc.com/id/01a0f0af-c629-72e9-a2af-adeff5d9868a) › [40 CFR Part 1065, Subpart D, Subject Group: NOX and N2O Measurements—NOX and N2O Measurements](https://ontology.bommaritollc.com/id/01a0f0af-c632-7305-a025-04a52b6b4ebe)

Type: [schema:Legislation](https://schema.org/Legislation)

- `adms:identifier`: [cfr-section 40 CFR 1065.370](https://ontology.bommaritollc.com/id/01a0f0b0-6d7e-7768-9dd9-4908bac0aa92)
- `eli:cites`:
  - [40 CFR 1065.145 Gaseous and PM probes, transfer lines, and sampling system components.](https://ontology.bommaritollc.com/id/01a0f0b0-6d31-7202-bc07-c01b1efa7323)
  - [40 CFR 1065.248 Gas divider.](https://ontology.bommaritollc.com/id/01a0f0b0-6d45-775d-8ad2-49c3e9758201)
  - [40 CFR 1065.342 Sample dryer verification.](https://ontology.bommaritollc.com/id/01a0f0b0-6d70-7157-8360-274af885c42d)
  - [40 CFR 1065.675 CLD quench verification calculations.](https://ontology.bommaritollc.com/id/01a0f0b0-6dc0-7677-aa39-e77730354d09)
  - [40 CFR 1065.750 Analytical gases.](https://ontology.bommaritollc.com/id/01a0f0b0-6dda-7161-bc9d-96f18e5bdf97)
- `prov:wasDerivedFrom`:
  - [evidence from https://www.govinfo.gov/app/details/CFR-2025-title40-vol1](https://ontology.bommaritollc.com/id/01a0f0b0-6d7d-73a2-90f0-307eae0da275)
  - [evidence from https://www.govinfo.gov/app/details/](https://ontology.bommaritollc.com/id/01a0f0b0-b87d-750b-8306-d399a93cb85b)
  - [evidence from https://www.govinfo.gov/app/details/](https://ontology.bommaritollc.com/id/01a0f0d1-8b4d-7731-b565-4328acdb6353)
  - [evidence from https://www.govinfo.gov/link/cfr/40/1065?sectionnum=370&year=mostrecent&link-type=details](https://ontology.bommaritollc.com/id/01a10f17-f46f-729c-afd7-48cb4b71fbc9)
- `schema:isPartOf`: [40 CFR Part 1065, Subpart D, Subject Group: NOX and N2O Measurements—NOX and N2O Measurements](https://ontology.bommaritollc.com/id/01a0f0af-c632-7305-a025-04a52b6b4ebe)
- `schema:legislationIdentifier`: 40 CFR 1065.370
- `schema:legislationJurisdiction`: [United States](https://ontology.bommaritollc.com/id/01a0ed8e-f797-7004-b7f5-bec2695977c0)
- `schema:legislationLegalForce`: [schema:InForce](https://schema.org/InForce)
- `schema:legislationType`: [CFR section](https://ontology.bommaritollc.com/vocab/leg/cfrSection)
- `schema:name`: CLD CO2 and H2O quench verification
- `schema:url`: [https://www.govinfo.gov/link/cfr/40/1065?sectionnum=370&year=mostrecent&link-type=details](https://www.govinfo.gov/link/cfr/40/1065?sectionnum=370&year=mostrecent&link-type=details)
- `skos:prefLabel`: 40 CFR 1065.370 CLD CO2 and H2O quench verification.

## Elsewhere

- [Official page](https://www.govinfo.gov/link/cfr/40/1065?sectionnum=370&year=mostrecent&link-type=details) (www.govinfo.gov)
- [Source](https://www.govinfo.gov/app/details/CFR-2025-title40-vol1) (www.govinfo.gov)
- [Source](https://www.govinfo.gov/app/details/) (www.govinfo.gov)

## Pointing here

- Cited by (5; `eli:cites`):
  - [40 CFR 1065.270 Chemiluminescent NOX analyzer.](https://ontology.bommaritollc.com/id/01a0f0b0-6d51-74d9-9571-5f9fab70a5aa)
  - [40 CFR 1065.303 Summary of required calibration and verifications.](https://ontology.bommaritollc.com/id/01a0f0b0-6d60-7422-89f6-327a1f1e5ec2)
  - [40 CFR 1065.675 CLD quench verification calculations.](https://ontology.bommaritollc.com/id/01a0f0b0-6dc0-7677-aa39-e77730354d09)
  - [40 CFR 1066.130 Measurement instrument calibrations and verifications.](https://ontology.bommaritollc.com/id/01a0f0b0-6e1b-76a8-85a7-5a68b9917843)
  - [40 CFR 1066.150 Analyzer interference and quench verification limit.](https://ontology.bommaritollc.com/id/01a0f0b0-6e20-7584-ba06-ca2c50c96f99)

---
Also as: [Turtle](https://ontology.bommaritollc.com/id/01a0f0b0-6d7d-73a2-90f0-307f63992b83.ttl), [JSON-LD](https://ontology.bommaritollc.com/id/01a0f0b0-6d7d-73a2-90f0-307f63992b83.jsonld), [N-Triples](https://ontology.bommaritollc.com/id/01a0f0b0-6d7d-73a2-90f0-307f63992b83.nt), [HTML](https://ontology.bommaritollc.com/id/01a0f0b0-6d7d-73a2-90f0-307f63992b83)
Cite as: 40 CFR 1065.370 CLD CO2 and H2O quench verification.. bc-ontology, release 0.1.0-rc38, 2026-10-21. https://ontology.bommaritollc.com/id/01a0f0b0-6d7d-73a2-90f0-307f63992b83
Release 0.1.0-rc38, graph hash 05350a11cf9d0c42fba51e92b877115781ab65cb92afcd6b172ff9f8f4abf0bd.
